Step | | Procedure & Parts & Tools |
1 |
|
LIFT THE RECOVERY TANK FROM THE MACHINE AND CARRY TO DRAIN TO EMPTY. PUSH THE MACHINE OVER A DRAIN AND REMOVE THE YELLOW SOLUTION FILTER CAP TO DRAIN THE SOLUTION TANK.
|
2 |
|
RAISE THE TANK COVER UP UNTIL IT POPS OFF MACHINE.
|
3 |
|
LOCATE THE 2 HOSES COMING UP THRU THE SOLUTION TANK. PULL THE HOSE CUFFS OFF HOSES.
|
4 |
|
CHECK THE SQUEEGEE VAC HOSE FOR LEAKS. NOTE: THIS HOSE IS THE TALLEST OF THE 2 HOSES. STANDING IN THE OPERATOR POSITION, THIS HOSE IS ON THE RIGHT.
|
5 |
|
REMOVE THE 4 BOLTS HOLDING THE BATTERY COVER.
Torx T30 |
|
|
6 |
|
SLIDE BOTH BATTERIES FROM THE BATTERY COMPARTMENT. NO NEED TO DISCONNECT THE CABLES.
|
7 |
|
REMOVE THE 2 BOLTS IN THE BATTERY COMPARTMENT.
Torx T30 |
|
|
8 |
|
LOOSEN THE BOLT ON THE FRONT OF THE SOLUTION TANK.
Torx T30 |
|
|
9 |
|
REMOVE THE 2 SOLUTION TANK BOLTS ON EACH SIDE OF THE TANK.
Torx T30 |
|
|
10 |
|
RAISE THE SOLUTION TANK UP SO THE HOSE IS VISIBLE WHERE IT CONNECTS TO THE SQUEEGEE ASSEMBLY.
|
11 |
|
CHECK THE SQUEEGEE VAC HOSE FOR LEAKS AND MAKE SURE IT IS CONNECTED TIGHTLY TO THE SQUEEGEE ASSEMBLY.
|
12 |
|
IF THE SQUEEGEE VAC HOSE IS OKAY, REVERSE STEPS 1 THRU 11 TO REASSEMBLE THE MACHINE.
|