USAfixTM - Repair Guide (RG) - Master Email RG
- Check the squeegee vacuum hose for leaks
 Level of Difficulty - MEDIUM  Estimated Completion Time - 35 minutes
TASKI - SWINGO 350B

Tools Required
Tool 
Torx T30

Parts Required


Step Procedure & Parts & Tools
1 LIFT THE RECOVERY TANK FROM THE MACHINE AND CARRY TO DRAIN TO EMPTY. PUSH THE MACHINE OVER A DRAIN AND REMOVE THE YELLOW SOLUTION FILTER CAP TO DRAIN THE SOLUTION TANK.

2 RAISE THE TANK COVER UP UNTIL IT POPS OFF MACHINE.

3 LOCATE THE 2 HOSES COMING UP THRU THE SOLUTION TANK. PULL THE HOSE CUFFS OFF HOSES.

4 CHECK THE SQUEEGEE VAC HOSE FOR LEAKS. NOTE: THIS HOSE IS THE TALLEST OF THE 2 HOSES. STANDING IN THE OPERATOR POSITION, THIS HOSE IS ON THE RIGHT.

5 REMOVE THE 4 BOLTS HOLDING THE BATTERY COVER.
Torx T30

6 SLIDE BOTH BATTERIES FROM THE BATTERY COMPARTMENT. NO NEED TO DISCONNECT THE CABLES.

7 REMOVE THE 2 BOLTS IN THE BATTERY COMPARTMENT.
Torx T30

8 LOOSEN THE BOLT ON THE FRONT OF THE SOLUTION TANK.
Torx T30

9 REMOVE THE 2 SOLUTION TANK BOLTS ON EACH SIDE OF THE TANK.
Torx T30

10 RAISE THE SOLUTION TANK UP SO THE HOSE IS VISIBLE WHERE IT CONNECTS TO THE SQUEEGEE ASSEMBLY.

11 CHECK THE SQUEEGEE VAC HOSE FOR LEAKS AND MAKE SURE IT IS CONNECTED TIGHTLY TO THE SQUEEGEE ASSEMBLY.

12 IF THE SQUEEGEE VAC HOSE IS OKAY, REVERSE STEPS 1 THRU 11 TO REASSEMBLE THE MACHINE.